A-61124 March 1999 5-25
Send command
Send is required when executing scanner-unique commands.
Command op code: 2AH
SCSI Specification: Section 14.2.8
Command block descriptor
Bit
Byte
7 6543210
0 Operation Code (2AH)
1 Logical Unit Number Reserved RelAdr
2 Transfer Data Type
3 Reserved
4 Transfer Identification
5 (LSB)
6 (MSB) Transfer Length
7
8 (LSB)
9 Vendor Unique Reserved Flag Link
Send data
Descriptor Data Definition
Logical Unit Number = 0 Only one logical unit
RelAdr = 0 Not supported
Transfer Type* = 80 Scanner-unique command
Transfer ID = 0 Not used
Transfer Length* = length Maximum number of bytes to transfer
*The maximum number of bytes which can be transferred is 256.