5-6 A-61124 March 1999
SCSI conformance
The scanner conforms to the SCSI specifications as follows:
Single-ended, 8-bit bus, Cable A, shielded connector
(Alternative 2). Cable B is not supported.
Single-initiator (one host) is supported. Disconnect and
Reselect are not supported.
Asynchronous maximum transfer rate of 1.2 M Bytes per
second.
Linked commands and command queuing are not supported.
Programmable target ID dip switch is factory set to 1.
RST signal reset is only monitored. See the hard reset
alternative in SCSI Specifications (Section 5.2.2.1).
The scanner supports Unit Attention condition following
power-up, SCSI bus device reset command or hard reset.
Refer to Section 6.13 of SCSI Specifications.
The scanner operates as a target.
The internal SCSI cable consumes 5 feet (1.5 meters) of the
maximum cable length allowed (19.7 feet/6 meters).
The scanner provides termination power.